Lithium-ion battery analyzer is a professional battery tester, equipped with battery testing software and data processing software, suitable for battery R&D and quality control testing needs.
Model:
WA-BTS-5V5ATest channels:
8CH/SET (Customizable)Voltage range/CH:
0V~5V (Customizable)Voltage accuracy:
0.02%RD + 0.02%FSCurrent range/CH:
5mA~5A (Customizable)Current accuracy:
0.02%RD + 0.02%FSWarranty:
One year warranty with lifetime supportProduct Detail
Lithium-ion Battery Analyzer
Product overview:
The lithium-ion battery analyzer is a professional battery tester, equipped with battery testing software and data processing software, suitable for battery R&D and quality control testing needs, such as charge and discharge testing, cycle life testing, formation and capacity grading, etc.
Lithium-ion Battery Analyzer (Both voltage and current can be customized) |
||
Product model |
Voltage range / CH |
Current range / CH |
WA-BTS-5V200mA |
0V~5V |
0.1mA~200mA |
WA-BTS-5V500mA |
0V~5V |
0.1mA~500mA |
WA-BTS-5V1A |
0V~5V |
1mA~1A |
WA-BTS-5V3A |
0V~5V |
3mA~3A |
WA-BTS-5V5A |
0V~5V |
5mA~5A |
WA-BTS-5V6A |
0V~5V |
6mA~6A |
WA-BTS-5V10A |
0V~5V |
10mA~10A |
For more product models, please click "Battery Test Systems" to view or contact us. |
Scope of application:
The lithium-ion battery analyzer is suitable for the test of battery cells, the test current range is 5mA~5000mA, and the test clamps are equipped according to the battery type.
Features:
1) Independent control for each channel
The lithium-ion battery analyzer is an 8-channel battery analyzer, each channel is independent, can be independently programmed, and can be independently controlled.
2) High test accuracy
The lithium-ion battery analyzer has high test accuracy, voltage accuracy: 0.02%RD + 0.02%FS, current accuracy: 0.02%RD + 0.02%FS.
3) The programming of test steps is simple
The software uses the full-screen table format work step programming interface, which is simple and easy to use.
4) Support multiple test steps
The lithium-ion battery analyzer supports constant current charging, constant current discharge, constant voltage charging, constant power charging, rate charging, rate discharging, constant resistance discharging and standing and other test steps.
5) Support multiple test end conditions
The test end conditions support more than 20 settings such as time, voltage, current, capacity, and -∆V.
6) Powerful safety protection function
The battery analyzer has protection methods such as over-voltage, under-voltage, over-charge current, over-discharge current, over-charge capacity, and over-discharge capacity, etc.
7) With power-down protection function
During the battery test process, any time there is a power failure in the power supply system, the battery analyzer can guarantee that no data will be lost. After power on again, the lithium-ion battery analyzer has a self-recovery function, which can seamlessly connect from the place where it was powered off last time and continue the test process.
8) Powerful test data processing function
The software has powerful test data and graphics processing functions.
Technical specifications
Product name |
Battery Test Systems |
|
Product model |
WA-BTS-5V5A |
|
Number of channels / Set |
8CH |
|
Power supply |
Single-phase AC220V±10% / 50Hz (Customizable) |
|
Input active power |
200W |
|
Input Resistance |
≥1GΩ |
|
Resolution |
AD:16bit; DA:16bit |
|
Voltage |
Voltage Range / Channel |
0V~5V (Customizable) |
Discharge Min Voltage |
0V |
|
Accuracy |
0.02%RD + 0.02%FS |
|
Stability |
± 0.02% of FS |
|
Current |
Current Range / Channel |
5mA~5000mA (Customizable) |
Accuracy |
0.02%RD + 0.02%FS |
|
Constant Voltage Cut-off Current |
50μA |
|
Stability |
± 0.02% of FS |
|
Power |
Output Power / Channel |
25W |
Stability |
±0.1% of FS |
|
Time |
Current Response Time (10%FS~90%FS) |
<200μs |
Step Time Range |
00:01~4800:00:00 |
|
Supported time format |
00:00:00:00(h、min、s、ms) |
|
Data Recording |
Recording Condition |
The minimum time interval:100ms |
The minimum voltage interval:2mV |
||
The minimum current interval: 10μA |
||
Record Frequency |
5Hz |
|
Charge |
Charge Mode |
Constant Current Charge, Constant Voltage Charge, Rate Charge, etc. |
End Condition |
Voltage, Current, Relative Time, Capacity, -ΔV, etc. |
|
Discharge |
Discharge Mode |
Constant Current Discharge, Constant Voltage Discharge, Rate Discharge, etc. |
End Condition |
Voltage, Current, Relative Time, Capacity, etc. |
|
Cycle |
Loop Measure Range |
1~99999 times |
Max Steps Per Loop |
400 |
|
Nested Loop |
Nested loop Function,Max Support 3 Layers |
|
Protection |
Software Protection |
Power down data protection, automatic seamless start after power on. |
Setting Protection Condition,Setting Parameter: Upper limit of Voltage、Lower limit of Voltage、Upper limit of Current、Lower limit of Current、Upper limit of Capacity、Temperature、Delay Time |
||
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage and current test collection method |
4-wire connecting |
|
Noisy |
<45dB |
|
Server operating system |
Win 7, Win 8, Win 10, etc. |
|
Data Output |
EXCEL 2003, EXCEL 2010, TXT |
|
Leakage current |
0.001μA |
|
communication method |
RS232 |
|
Communication Interface |
Aviation connector |
|
Working Temperature Range |
0℃~40℃ |
|
Storage Temperature Range |
-10℃~50℃ |
|
Working Environment Relative Humidity Range |
≤70% RH |
|
Storage Environment Relative Humidity Range |
≤80% RH |
|
Size(W*D*H) |
450*340*90mm |
|
Weight |
6kg |