In battery pack testing, the battery cell voltage monitor acts as AUX auxiliary channels to provide auxiliary cell-voltage inputs to the battery cycler to monitor the multi cell voltage in real time.
Brand:
WinAckModel:
WA-BTS-AUX-VBTest channels:
8CH/SETVoltage range/CH:
10mV~5V (Device port)Voltage accuracy:
±0.05% FSR (Customizable)Delivery time:
0~7 days (Negotiable)Product Detail
Battery Cell Voltage Monitor
AUX Auxiliary Channels for Battery Cycler
Product Overview:
The battery cell voltage monitor is an auxiliary battery cell voltage monitoring system for DB-series battery cyclers and RB-series battery cyclers. And, use the same operating software as the battery cycler.
After connecting to the battery cycler and PC via an Ethernet switch, the battery cell voltage monitor can sample the multi-cell voltages, which will be recorded together with the test data and can be used as a test variable condition.
Scope of Application:
In battery module testing and battery pack testing, the battery cell voltage monitor acts as AUX auxiliary channels to provide auxiliary cell-voltage inputs for DB-series battery cyclers and RB-series battery cyclers.
It is a real-time battery cell voltage monitoring system that can not only evaluate battery cell performance in more detail, but also provide cell overcharge protection and cell over discharge protection for battery testing.
Technical Specifications of Battery Cell Voltage Analyzer
Product name |
Battery Cell Voltage Sampler |
|
Product model |
WA-BTS-AUX-VB |
|
AC input voltage (Customizable) |
Single-phase 220VAC±10% / 50Hz |
|
Power |
300W |
|
Input impedance |
≥1MΩ |
|
No. of channels |
8 Channels/Cabinet |
|
Voltage range/CH |
DC: 10mV~5V (Device port) |
|
Voltage accuracy |
±0.05% FSR (Customizable) Note: Ambient temperature:15~35℃. |
|
Data recording |
Recording frequency |
1Hz Note: 10Hz is customizable. |
Recording conditions |
∆T, ∆I, ∆V |
|
Min. time interval |
1s Note: If 10Hz, then 100ms. |
|
Min. voltage interval |
1mV or 0.01%FSR |
|
Communication interface |
Ethernet |
|
PC operating system |
Micorsoft Windows |
|
Test data output |
Excel and PDF |
|
Cooling method |
Forced air-cooling |
|
Machine noise |
≤50dB |
|
Operating temperature |
0℃~40℃ |
|
Storage temperature |
-10℃~50℃ |
|
Working Environment Relative Humidity |
≤70% RH (No condensation) |
|
Storage Environment Relative Humidity |
≤80% RH (No condensation) |
|
Sampling clamp cables (Standard: 0.5m in length.) |
Small alligator clamps |
Figure 1. Battery Cell Voltage Monitoring System for Battery Cycler
* Reference picture (Picture just as reference, please in kind prevail)